3.2.9 Mold adjustment screen
Fig 3-41
Mold adjustment screen
Operating sequences
Press the mold adjustment key to enter the mold adjustment screen.
Press Mold adjustment mode key
on the operator panal to make
the machine at mold adjustment status. The indicators
②
on the screen
(see table 3-1) is flashing to inform users that the machine is under
adjustment.
The system provides two mold adjustment modes: pulse adjustment and
automatic adjustment.
For pulse adjustment, users can set pulse value for mold adjustment.
For automatic adjustment, users should first set time. If mold adjustment
does not finish within the preset time, then the system will retract the
mold automatically.
Mold close during mold adjustment (MldClo)
-
in mold adjustment
mode, set the pressure and flow during mold close.
Mold open during mold adjustment (MldOpn)
-
in mold adjustment
mode, set the pressure and flow during mold open.
Carriage movement during mold adjustment (Carriage)
-
in mold
adjustment mode, set the pressure and flow during carriage movement.
Ejector during mold adjustment (Ejector)
-
in mold adjustment mode,