SIJECT
OP15B
Screens
SIJECT 15/16 Operation Manual
3-45
3.2.5 Charging screen
Fig
3-35 Charging
screen
Operating sequences
Press the Charging key to enter the charging screen. See Fig 3-35.
Four charging statuses are provided on the screen, and related
parameters can be set here, including position, pressure and flow. In
addition, backpressure can be selected to set the pressure.
Pre-decompression (PreDec)
-
implement decompression before
charging, and the position, pressure and flow can be set here.
Charging 1 (Charge 1)
-
set the position, pressure and flow for
charging 1. If proportional backpressure valve is used, then the value
should be set as backpressure.
Charging 2
(Charge 2)
-
set the position, pressure and flow for
charging 2. If proportional backpressure valve is used, then the value
should be set as backpressure.
Charging 3
(Charge 3)
-
set the position, pressure and flow for
charging 3. If proportional backpressure valve is used, then the value
should be set as backpressure.
Charging 4 (Charge 4)
-
set the position, pressure and flow for
charging 4. If proportional backpressure valve is used, then the value
should be set as backpressure.
Decompression (Dec)
-
implement decompression after charging, and
the position, pressure and flow can be set here.
Back pressure selection (BP Select)
-
you can select the proportional
backpressure valve or deselect it.
Screw position (ScwPos)
-
display the current position of screw.