SIJECT OP15B Screens
SIJECT 15/16 Operation Manual June, 2003
3-54
Injection during mold adjustment (Inject)
-
in mold adjustment mode,
set the pressure and flow during injection.
Suck back during mold adjustment (SuckBck)
-
in mold adjustment
mode, set the pressure and flow during suck back (decompression).
Charging during mold adjustment (Charge)
-
in mold adjustment
mode, set the pressure and flow during charging.
Mold advance during mold adjustment (Advance)
-
in mold
adjustment mode, set the pressure and flow during mold advance.
Mold retract during mold adjustment (Retract)
-
in mold adjustment
mode, set the pressure and flow during mold retract.
Pulse of mold advance (AdvPuls)
-
in pulse mold adjustment mode,
set the pulse of mold advance.
Pulse of mold retract (RetPuls)
-
in pulse mold adjustment mode, set
the pulse of mold retract.
Pulse mold adjustment
(PulsAdj)
– select or deselect.
Mold close time (MldCloTim)
-
in Auto adjustment mode, set the mold
close time for mold adjustment. Users can set an initial value and the
system will judge it automatically. If mold cannot be adjusted within this
time, then the system will retract the mold to fulfil automatic adjustment.
Auto mold adjustment (AutoAdj)
-
select or deselect.
Current status (CurStatus)
-
display the pressure and flow of current
system.
When pulse adjustment mode is selected, press advance key
and
the system will run the set pulse to make the mold advance. Press
retract key
and the sytem will run the set pulse to make the mold
retract.
When auto adjustment mode is selected, press soft key F4 “Auto Start”
to start the auto mold adjustment; and press F5 “Auto Stop” to end the
adjustment.