Mold position (MldPos)
-
display the current position of mold.
Press Manual Core 1 in key
to do core in manually, and press
Manual Core 1 out key
to do core out.
Fig 3-37
Core 1 in/out --- screen 2
On Core 1 screen 1 (see Fig 3-36), press softkey F5
to enter Core
1 screen 2. See Fig 3-37. Core 3 in/out can be set here.
The screen displays the core 1 in/out status, and the related parameters
can be set here, including the position, pressure, flow, time and counter.
The core operation can be controlled by position, by time, or by counter.
Core 3 in
-
set the pressure and flow for core 3 in. If it is by position,
then position value should be set. If it is by time, then the time should be
set as a parameter and the actual time will be displayed. If it is by
counter, then the counter should be set and the actual counting value will
be displayed.
Core 3 out
-
set the pressure and flow for core 3 out. If it is by position,
then position value should be set. If it is by time, then the time should be
set as a parameter and the actual time will be displayed. If it is by
counter, then the counter should be set and the actual counting value will
be displayed.
Core 3 selection (CorSelect)
-
select or deselect core 3 in/out.
Core 3 mode (CorMode)
-
select position mode, time mode or counter