Operating sequences
Press Information key to enter the Information screen 1 and current
system information will display, i.e., OP version, CI version and PLC
version. See Fig 3-4, Information screen 1.
Press soft key F1
and OEM customer specific picture will display.
See Fig 3-5, Information screen 1.1 --- OEM picture. Siemens can realize
specific requirements if customers have any, such as displaying
company name, address, symbol, etc.
Press soft key F3
to display the status of all 32 digit inputs
(
24
digit inputs for SIJECT15
+
)
. The box will backlight if there is a signal.
See Fig. 3-6, Information screen 1.2 --- digit inputs. Users can check the
status of each input/output.
Press soft key F4
to display the status of all 40 digit outputs
(
35
digit outputs for SIJECT15
+
. DQ3.5 ~ DQ3.7 and DQ 4.6~DQ 4.7 are
spare). The box will backlight if there is a signal. See Fig. 3-7,
Information screen 1.3 --- digit outputs.
Force Output is to make certain point force output. For example, input
3.4 and press softkey F2 “Force Output”. Now DQ3.4 on the screen will
backlight, and this point in the system will give output and LED on.
Press softkey F2
to enter the next screen. See Fig 3-8,
Information screen 2. The type of CI and the position of PLC switches
are displayed here. When PLC powers on, the system will check the
running status of PLC automatically, such as PLC startup, PLC cycle, OP
communication and CI EPROM.