SIJECT
OP15B
Screens
SIJECT 15/16 Operation Manual
3-31
Fig 3-26
Service screen 1.3 – Proportional valve adjustment
Operating sequences
Press softkey F5
to enter proportional valve adjustment screen.
See Fig. 3-26 Service Screen 1.3 --- proportional valve adjustment.
Proportional valve can be adjusted here, and you can test pressure, flow
and back-pressure in force output mode.
Adjust Valve
--- select On/Off to start valve adjustment.
Valve Type
--- select the type of valve: flow / pressure / back-pressure /
reserved.
Valve Limit
--- select min. / max. value.
Pressure Test
--- in force output mode, input pressure value, ranged
from 0
~
140bar.
Flow Test
--- in force output mode, input flow value, ranged from
0
~
100
%
.
BackPressure Test
--- in force output mode, input pressure value,
ranged from 0
~
140bar.
Operating sequences
Firstly, start valve adjustment:
Select “ON” in Adjust Valve mode:
1. Use cursor key
or
to enter valve adjustment selection;
2.
Press
selection
key , and the cursor moves to left;
3. Use cursor key
or
to select “ON”;
4. Press Enter key to confirm.