SIJECT OP15B Screens
SIJECT 15/16 Operation Manual June, 2003
3-40
3.2.2 Ejector screen
Fig
3-32 Ejector
screen
Operating sequences
Press the middle key to enter the ejector screen. See Fig 3-32.
Four status of the ejector advance / retract are displayed on the screen:
ejector advance 1, ejector advance 2, ejector retract 1 and ejector retract
2.
All related parameters can be set here, including position, pressure, flow
and counter. When Vibrate is selected, then the vibration position can
also be set.
Ejector advance 1 (EjeAdv 1)
-
During ejector advance, users can set
position, pressure and flow for ejector advance 1.
Ejector advance 2 (EjeAdv 2)
-
During ejector advance, users can set
position, pressure and flow for ejector advance 2.
Ejector retract 1(EjeRet 1)
-
During ejector retract, users can set
position, pressure and flow for ejector retract 1.
Ejector retract 2(EjeRet 2)
-
During ejector retract, users can set
position, pressure and flow for ejector retract 2.
Vibrating position (Vibrate)
-
Set position here. Ejector retracts to this
position and then advances. This is so called vibration ejection.
Ejector backward indicator (EjeBck)
-
when ejector retracts to the end
position, this indicator will backlight, indicating that the end position signal
has been detected.
Ejector mode (EjeMode)
-
users can select once, multiple or vibration
mode. Once mode: ejector advances after mold open, but it will not
retract. Multiple mode: ejector advances and retracts to the end position,