148
SDH Series Manual
Digital output (DO) function definition
Sign
Initial
value
Functions/Applications description
RD
0x01 As the drive is ready to be operated, RD-SG would become conductive.
ALM
0x02 ALM-SG is isolated as power off or protection activated to cut off the main circuit. Without alarm
occurring, ALM-SG would turn on after power on 1 second latter.
INP/SA 0x 03 In position mode, INP-SG is conductive as position errors is under permissible range.
In speed mode, SA-SG is conductive as the motor speed has nearly attained.
HOME 0x 04 HOME-SG is on after the completion of home moving.
TLC/
VLC
0x 05
In speed mode, TLC-SG is on as motor generated torque reaches inner torque limit or torque analog
limit. TLC-SG is off when SON signal is turned off.
In torque mode, VLC-SG is on as motor speed reaches inner speed limit or speed analog limit. VLC-SG
is off when SON signal is turned off.
MBR
0X06 When using this signal, make it usable by setting parameter PA01 as □1□□. MBR is off as the power is
turned off or any alarm occurred.
WNG 0x 07 WNG-SG is conductive as any warning occurred. Without warning occurring, WNG-SG is isolated
ZSP
0x 08 When motor speed is under the preset of zero speed, ZSP-SG keeps conductive.
CMDOK 0x 09 CMDOK-SG is conductive as the inner position command is completed or stopped.
OLW
0x0A When reaching the overload setting(PA17), this DO is ON
MC_OK 0x0B When CMDOK and INP is both ON, this DO is ON.
OVF
0x0C When motor position command pulse is more than 2
31
-1or less than -2
31
, this DO is ON.
SWPL 0x0D When the motor feedback pulse more than software forward limit (PF86), this DO is ON.
SWNL 0x0E When the motor feedback pulse less than software reverse limit (PF87), this DO is ON.
ABSW
0x0F Absolute encoder related alarm is from this DO output.
Note: DO output logic level can be set to determine the output PD27 a normal open a or normal close ab.
Содержание SDH Series
Страница 1: ...SDH Series Manual ...
Страница 2: ......
Страница 22: ...13 Chapter 3 100W 1kW Shihlin servo driver Power source 100W 15KW 3Φ200 230Vac ...
Страница 190: ...181 Chapter 12 12 5 Dimensions of low inertia motor SMH L010 SMH L020 L040 SMH L075 ...
Страница 196: ...187 Chapter 13 As load torque is 300 operating time is 2 23S As load torque is 300 operating time is 2 28S ...
Страница 219: ......
Страница 220: ...2016 ...