45
Chapter 4.
4.3 Status display
The operation status of Shihlin servo could be displayed on the 5-digit 7 segment LED display.
Press the “UP” or “DOWN” key to change the display data as desired.
When the required data is selected, the corresponding symbol appears. Press the “SET” key to display the information.
7 segment LED display could show the 5 digits of 16 items such as motor speed.
A negative value which occupies 5 digits is displayed by the 5 lit decimal points. If a negative value which occupies only 4
digits or less, the negative symbol “-“ is displayed at the highest digit.
Examples
The following table lists the display examples:
Item
Status
Display device
7 segment LED display.
Motor rotation speed
Forward rotation at 500r/min
Reverse rotation at 3000r/min
The ratio of load inertia to motor shaft
15.5times
Motor feedback revolution
(high digit)
Value is 1234567890
Display high digit
->
1234.5
Motor feedback revolution
(low digit)
Value is1234567890
Display low digit -> 67890.
Parameter setting accomplished
a successful write-in
Parameter setting failed
Servo on (SON on)
a failed write-in
Please do SON off and write-in again.
Parameter setting over range
Parameter setting over range
Write-in parameter setting value again
PS: The details of display panel, please refer to the parameter value of section 1.6 for examples
NOTE
:
When setting the panel parameters, each parameter has the high/low limit values range.
When the decimal data changes, value has high/low limit.
When the hexadecimal data changes, Hex value has high/low limit.
Содержание SDH Series
Страница 1: ...SDH Series Manual ...
Страница 2: ......
Страница 22: ...13 Chapter 3 100W 1kW Shihlin servo driver Power source 100W 15KW 3Φ200 230Vac ...
Страница 190: ...181 Chapter 12 12 5 Dimensions of low inertia motor SMH L010 SMH L020 L040 SMH L075 ...
Страница 196: ...187 Chapter 13 As load torque is 300 operating time is 2 23S As load torque is 300 operating time is 2 28S ...
Страница 219: ......
Страница 220: ...2016 ...