160
SDH Series Manual
Address : 0x020C
Bit10~Bit14
Bit5~bit9
Bit0~bit4
Bit No.
DO3
DO2
DO1
Signal name
0x00~0x1F
0x00~0x1F
0x00~0x1F
Function
Address : 0x020D
Bit10~Bit14
Bit5~bit9
Bit0~bit4
Bit No.
DO6
DO5
DO4
Signal name
0x00~0x1F
0x00~0x1F
0x00~0x1F
Function
(c) Current control mode
Address
Content
Data length
0x0200
Bit0 : servo drive is ready (0:Servo OFF, 1:Servo ON )
1word
0x0201
Bit0~Bit3 : To display current control mode of servo drive.
0
:
Pt mode
,
1
:
Pr mode (inner register command in absolute type)
2
:
Pr mode (inner register command in incremental type)
3
:
S mode
4
:
T mode
5Fully closed loop control mode
1word
Note 1
:D
I function definition
0x07
0x06
0x05
0x04
0x03
0x02
0x01
0x00
Function
code
SP2
SP1
TL1
TL
PC
RES
SON
-
Sign
0x0F
0x0E
0x0D
0x0C
0x0B
0x0A
0x09
0x08
Function
code
CR
CM2
CM1
SHOM
ORGP
ST2/RS1
ST1/RS2
SP3
Sign
0x17
0x16
0x15
0x14
0x13
0x12
0x11
0x10
Function
code
CTRG
POS3
POS2
POS1
EMG
LOP
CDP
Sign
0x1F
0x1E
0x1D
0x1C
0x1B
0x1A
0x19
0x18
Function
code
EV2
EV1
INHP
POS6
POS5
POS4
LSN
LSP
Sign
0x24
0x23
0x22
0x21
0x20
Function
code
STOP
ABSC
ABSE
EV4
EV3
Sign
Note 2
:
DO function definition
0x05
0x04
0x03
0x02
0x01
0x00
Function code
TLC/VLC
HOME
INP/SA
ALM
RD
-
Sign
0x0B
0x0A
0x09
0x08
0x07
0x06
Function code
MC_OK
OLW
CMDOK
ZSP
WNG
MBR
Sign
0x0F
0x0E
0x0D
0x0C
Function code
ABSW
SWNL
SWPL
OVF
Sign
(3)
Alarm information
(read only)
Address
Content
Data length
0x0100
Current alarm.
1word
0x0101
The last alarm.
1word
0x0102
The 2nd alarm in the past.
1word
0x0103
The 3rd alarm in the past.
1word
0x0104
The 4th alarm in the past.
1word
0x0105
The 5th alarm in the past.
1word
0x0106
The 6th alarm in the past.
1word
Note
:
When 0x00ffwas sent back means no alarm,0x0001means AL.01, 0x0012 means AL.12 and so on.
(4)
Alarm clear
(readable and writable)
Address
Content
Data length
0x0130
Clear current alarm if “0x1EA5” is written into this address.
Transmit current alarm code back if this address is read.
The setting range is 0~0xFFFF.
1word
0x0131
Clear all alarm histories if “0x1EA5” written data is address.
Transmit last alarm back if this address is read.
The setting range is 0~0xFFFF.
1word
Содержание SDH Series
Страница 1: ...SDH Series Manual ...
Страница 2: ......
Страница 22: ...13 Chapter 3 100W 1kW Shihlin servo driver Power source 100W 15KW 3Φ200 230Vac ...
Страница 190: ...181 Chapter 12 12 5 Dimensions of low inertia motor SMH L010 SMH L020 L040 SMH L075 ...
Страница 196: ...187 Chapter 13 As load torque is 300 operating time is 2 23S As load torque is 300 operating time is 2 28S ...
Страница 219: ......
Страница 220: ...2016 ...