124
SDH Series Manual
PA39
POL
(*)
Motor rotary direction option
The relation among motor rotary direction and input command
pulse-train direction and encoder output pulse direction is
described below.
0
z
y
x
x
:
input pulse-train and motor rotary direction option
x
motor rotary direction
forward pulse-train
input
reverse pulse-train input
0
CCW
CW
1
CW
CCW
y
:
motor rotary direction and encoder pulse output option
y
motor CCW rotation
motor CW rotation
0
1
z
:
encoder output option
0
:
output pulse
1
:o
utput division ratio
This parameter is related to PA 14
Pt.S.
T
0000h
0000h
~
0111h
-
PA40
SPW
(▲)
Special parameter write-enable
:
As this parameter is set as 0088h, the drive would take 2
seconds to recover factory-set. This change is valid by
power off once and power on again.
Pr.Pt
S.T
0000h
0000h
~
00FFh
-
PA41
POSPD
Max. speed output setting of encoder
According the actual application, users can set this PA41 to
optimize the encoder outputs (LA, LB). If this setting value is
exceeded during the motor running, the AL30 will occur. “0” is to
disable this function.
Pr.Pt
S.T
5500
0
~
6000
rpm
No
Abbr.
Function description
Control
Mode
Initial
Value
Setting
range
unit
PA42
BLK
(*)
Parameter read/write inhibit option
PA42
PA□□
PB□□
PC□□
PD□□
PE□□
PF□□
0000h
◎
0001h
◎
X
0002h
◎
X
0003h
◎
X
0004h
◎
X
0005h
◎
X
0006h
X, but PA42 is excepted it is writable.
◎:
R/W enable, ○
:
R enable W inhibit, X
:
R/W inhibit
Note: When the parameter group is assigned to R/W
inhibit, it mean that the display will not show.
Pr.Pt
S.T
0000h
0000h
~
00FFh
-
PA43
ENB
(*)
Encoder type option
Set PA43 as 0, when the 20bit resolution encoder is used
Set PA43 as 1, when the 22bit resolution encoder is used
Set PA43 as 2, when the 23bit resolution encoder is used
Pr.Pt
S.T
0001h
0000h
~
0002h
-
Содержание SDH Series
Страница 1: ...SDH Series Manual ...
Страница 2: ......