120
SDH Series Manual
PA06 CMX
Electronic gear numerator
Pr. Pt
1
1
~
2
26
-
PA07 CDV
(▲)
Electronic gear denominator
The improper setting could lead to unexpected fast rotation so make sure to
set them in the state of SERVO OFF.
The proper range setting is:
Pulse command input CMX Position command
F1 CDV CMX
f2 = f1
‧
CDV
Note : limit condition : 1/50 < (CMX/CDV) < 64000
Pr. Pt
1
1
~
2
26
-
No
Abbr.
Function description
Control
Mode
Initial Value
Setting
range
unit
PA08 HSPD1 Home moving high speed option 1
Pr
100
1
~
2000
rpm
PA09 HSPD2 Home moving high speed option 2
Pr
20
1
~
500
rpm
PA10 RES1
Regenerative resistor value
Drive capacity
Default
Under 500W
100Ω
750W~1KW
40Ω
1.5KW~3.5KW
13Ω
5KW~7KW
8Ω
Pr. Pt
S. T
According to
spec, please
refer to the table
left.
10
~
750
Ohm
PA11
RES2
Regenerative resistor capacity
Drive capacity
Default
Under 500W
20W
750W~1KW
40W
1.5KW~3.5KW
100W
5KW~7KW
1000W
Pr. Pt
S. T
According to
spec, please
refer to the table
left.
0
~
3000
Watt
PA12
INP
In-position range
:
To define the permissible pulse error range of position pulse
commands. As positioning operation done, the INP signal of DO
would output.
Pt. Pr
41943
0
~
2
22
pulse
Содержание SDH Series
Страница 1: ...SDH Series Manual ...
Страница 2: ......
Страница 22: ...13 Chapter 3 100W 1kW Shihlin servo driver Power source 100W 15KW 3Φ200 230Vac ...
Страница 190: ...181 Chapter 12 12 5 Dimensions of low inertia motor SMH L010 SMH L020 L040 SMH L075 ...
Страница 196: ...187 Chapter 13 As load torque is 300 operating time is 2 23S As load torque is 300 operating time is 2 28S ...
Страница 219: ......
Страница 220: ...2016 ...