197
Chapter 14.
At the time of alarm reset
If an alarm occurs, turn off SON by detecting ALM. If an alarm has occurred, ABSM cannot be accepted. In the
reset state, ABSM can be input.
Home position setting
Point
Never make home position setting during command operation or servo motor rotation. It may cause
home position sift.
Move the machine to the position where the home position is to be set by performing manual operation such as
JOG operation. When CR is on for longer than 20 ms, the stop position is stored into the nonvolatile memory as the
home position absolute position data. When the servo on, set CR to on after confirming that INP is on. The number of
home position setting times is limited to 100,000 times.