90
SDH Series Manual
6.5.1 Position/speed hybrid mode
This hybrid mode is divided into 2 types in detail. i.e. Pt/S and Pr/S. The sequence chart of mode switch is
presented in the figure below.
Control mode could not be switched if the motor is at a high speed rotation. It could be performed as the zero
speed detection output a signal is ON. Yet it is recommended for users to switch control mode when the motor is stopped
completely
6.5.2 Speed/torque hybrid mode
Set the PA01 as 1003H before this hybrid mode performed. Users could use LOP signal to switch speed mode and
torque mode. Because pin function ST1 (ST2) and RS2 (RS1) are defined mutually, the rotation direction of motor would
reverse while changing between the speed and torque modes.
The sequence diagram of the speed / torque mode is presented below.
It is recommended that users switch the speed to torque mode after the motor is static.