96
SDH Series Manual
The operation sequence of electromagnetic brake is plotted below.
Wiring diagram of electromagnetic brake (MBR DO applied)
Specification of electromagnetic brake:
Motor type
SMA series
L010B
L020B/L040B
L075B
M050B/M100B/M150B
M200B/M350B
Brake type
Spring brake (Normal locked)
Rated voltage (V)
DC 24V
Rated power (W)
6.3
7.9
8.6
19.3
34
Rated current (A)
0.24
0.32
0.35
0.8
1.41
Friction Tq (N
‧
m)
0.3
1.3
2.4
8.5
45
Electromagnetic brake is only provided for security of stopped motor, please don’t use at motor deceleration.