SDH Series Manual
3.1.2 Wiring diagram of peripheral devices-above 1.5KW
※
The details of EMI filter, please refer to Section 12.10 (EMI Filter)
To prevent electric shock, be sure to protect the servo drive ground (PE) terminal ( terminal tagged) connected to the
protective earthling protection cabinet (PE) on.
NOTE Installation instruction
:
•
Make sure the servo motor output terminals U/V/W are wired correctly.
•
When external brake resistor is used, make P/D ends open and connect the P/C ends to the external brake
resistor. If the built-in one applied, make P/D ends short and P/C ends open. Be sure that the brake resistor is
connected with the drive in operation.
•
Do not confuse R/S/T with L1/L2 or it causes the damage of servo.
DANGER
power supply
3-phase 200~230V
Magnectic
contactor
L
X10
N
Y10
CN3
CN2
CN1
Communication software
Host controller
or PLC
Servo motor
CN4
Main circuit
breaker
(NFB)
Make P/D open-circuit.
L1
、
L2
R
、
S
、
T
CN2L
Location feedback signal port
(option )
EMI filter