102
SDH Series Manual
S_LOW: The selection of speed unit: Bit 24=0 means the speed unit is 0.1 rpm; Bit 24=1 means the speed unit is 0.01
rpm.
AUTO: When the path completed, load to next path automatically.
DATA: Enable to set the coordinate value of each index positioning.
DATA Data format
Pulse: 0~1048575
The definition of home returning: Could be set by PE01 and PE02.
31~28
27~24
23~20
19~16
15~12
11~8
7~4
3~0 BIT
PE01
BOOT
x
DLY
x
DEC1
ACC
PATH
PE02
ORG_DEF (32 bit)
PATH: Enable to set the motion after home returning. The definition of PATH is shown below
:
PATH option
Bit 4~7
Bit 0~3
Description
0
0
Stop after home return
0
1
Perform PR#01 after home return
0
2
Perform PR#02 after home return
~
~
~
3
E
Perform PR#62 after home return
3
F
Perform PR#63 after home return
ACC: The range of value is 0~F. Enable to set acceleration time NO.
The definition is shown below.
ACC Value
F
E
D
C
B
…
4
3
2
1
0
Corresponding
parameter
PF64
PF65
PF64
PF63
PF62
…
PF53
PF52
PF51
PF50
PF49
DEC1: The range of value is 0~F. Enable to set the NO of first section deceleration time.
The definition is shown below.
ACC Value
F
E
D
C
B
…
4
3
2
1
0
Corresponding
parameter
PF64
PF65
PF64
PF63
PF62
…
PF53
PF52
PF51
PF50
PF49
The second section deceleration time is same as the STP deceleration time of PF81.
DLY: The range of value is 0~F. Enable to set delay time NO.
The definition is shown below.
DLY Value
F
E
D
C
B
…
4
3
2
1
0
Corresponding
parameter
PF80
PF79
PF78
PF77
PF76
…
PF69
PF68
PF67
PF66
PF65
BOOT: Set if run home return or not at the first servo ON.
BOOT option
Bit 28~31
Description
0
Do not run home return at the first servo ON.
1
Run home return at the first servo ON.
ORG_DEF: Defines the coordinate values of origin (not necessarily 0).
ORG_DEF data format
Pulse: (−2
31
) ~ (2
31
-1)
There is no function of origin stop mode in SDA drive which could set back to zero after home return.
Since after finding the origin (zero point signal or Z pulse), it must decelerate to stop and the position will be a short
distance beyond the origin, as shown below:
Содержание SDH Series
Страница 1: ...SDH Series Manual ...
Страница 2: ......
Страница 22: ...13 Chapter 3 100W 1kW Shihlin servo driver Power source 100W 15KW 3Φ200 230Vac ...
Страница 190: ...181 Chapter 12 12 5 Dimensions of low inertia motor SMH L010 SMH L020 L040 SMH L075 ...
Страница 196: ...187 Chapter 13 As load torque is 300 operating time is 2 23S As load torque is 300 operating time is 2 28S ...
Страница 219: ......
Страница 220: ...2016 ...