84
Operations
-48 VDC Remote Power Manager
Installation and Operations Manual
Setting the serial port timeout value:
The Set Port Timeout All command sets the serial port inactivity timeout period. The timeout period defines the
maximum period of inactivity before automatically closing the Pass-Thru session.
The valid range for the timeout is 0 to 60 (in minutes). The default timeout is 5 minutes. The command can be used to
set individual ports (by ID or name) or set all ports.
NOTES:
Setting the timeout value to “0” disables the timer.
Only a numeric value is accepted.
To set the serial port timeout value for an individual port:
At the Switched -48 VDC: prompt,
type set port timeout
, followed by the port ID or name, followed by a timeout
value from 0 to 60 (in minutes), and press
Enter
.
To set the serial port timeout value for all ports:
At the Switched -48 VDC: prompt, type
set port timeout all
, followed by a timeout value from 0 to 60 (in minutes),
and press
Enter.
Enabling or disabling the Serial Command Protocol (SCP) emulation:
This option notifies SCP of an MRV device on a specific serial port.
To enable or disable the SCP emulation:
At the Switched -48 VDC: prompt, type
set port scp
, followed by
emulate
, followed by
none
or
MRV
, and press
Enter
.
Enabling or disabling the RFTAG option:
This option makes RF Code sensor tags available for the Server Technology wireless monitoring solution.
To enable or disable the RF Code sensor options:
At the Switched -48 VDC: prompt, type
set port rftag
, follow by the serial port name, followed by
enabled
or
disabled
, and press
Enter
.
Displaying serial port information:
The Show Ports command displays information about all serial ports. This information includes:
Serial port data rate
Descriptive port name, if applicable
DSR signal checking settings
To display serial port information:
At the Switched -48 VDC: prompt, type
show ports
and press
Enter
.
Example
The following command displays all serial port information:
Switched -48 VDC: show ports<Enter>
Serial Port Configuration
Port ID: Console Port Name: CONSOLE
DSR Check: ON
CLI: Enabled SCP: Disabled RFTAG: Enabled
Data Rate: 9600
Connection Timeout: 10 minutes