Network wiring (Silver/StarNeT 1000)
2 - 18 • • • MPS-4100 product guide
Features
•
quick connection to network - removable terminal blocks for EIA-422 and ST
connectors for multi-mode fiber optic
•
network device address - DIP-switch-selectable (1 to 32 for Silver and 0 to 127
for StarNeT 1000)
•
StarNeT 1000 network baud rate - DIP-switch-selectable (Silver = 57.6 k)
•
dual redundant communications ports
•
network wiring enters through existing conduit outlet
•
receives power, ground and alarm data through 21-pin header on the Model
MPS-4100 Receiver card
•
fits in Model MPS-4100 Receiver unit enclosure (no modifications required)
•
low power consumption
•
diagnostic LED ON/OFF power switch for reduced power consumption
•
supports dual zone configuration (host/slave) with minimal additional wiring
from the second microwave unit to TB3
•
lightning suppression devices for communication circuits
•
on-board microprocessor
•
conformal coated PCB
•
16 diagnostic/status LEDs:
Software setup
For StarNeT 1000 systems, configure the MPS-4100 Microwave System in the
StarNeT site database as a
PLC-430/IWAVE Transponder
by following the
directions in the
SIMPL Site Creation Guide, J4DA0202
and the
Control Program
Maintenance Guide, J4DA0402
. Refer to the following point mapping tables for
MPS-4100 Silver Network point assignments.
LED
Function
LED
Function
POWER
power ON/OFF
ALARM 1 detection alarm HOST zone
TX A
transmitting data A-side
ALARM 2 detection alarm SLAVE zone
RX A
receiving data A-side
SUPVN 1 supervision alarm HOST
FAULT A CRC fault A-side
SUPVN 2 supervision alarm SLAVE
RESERVE future use
AUDIO 1 audio output HOST
TX B
transmitting data B-side
AUDIO 2 audio output SLAVE
RX B
receiving data B-side
TEST 1
self-testing HOST
FAULT B CRC fault B-side
TEST 2
self-testing SLAVE
Table 2-5 CIC LED functions