Stacking bistatic microwaves
MPS-4100 product guide • • • a - 11
Heavy snow areas
Snow accumulation decreases the effective mounting height. This moves the
operating point toward destructive phasing, which could result in degraded
performance. To compensate for snow accumulation, the setup of the upper unit
should be changed as follows:
•
Select the height of the upper pair to be at a point of destructive phasing
midway between two nodal lines. (As snow accumulates, the effective
mounting height will decrease and the operating point will shift toward
an area of constructive phasing).
Figure a-10 X-band sensor (MPS-4100, Series 14000, Series 16000)
Figure a-11 K-band sensor (Series 24000)
140
INCHES
CM
120
100
360
330
300
270
80
240
210
180
60
40
150
120
90
60
30
0
20
0
0
15
30
45
60
75
90
100
200
300
METERS
FEET
105
120 135
150 165
180
400
500
600
700
800
195
210 225
240
120
100
80
60
40
20
N 2
UNIT SEPARATION
N 1
N 3
N 4
140
MOUNTING
HEIGHT
INCHES
100
CM
255
240
210
180
150
120
90
60
30
0
0
20
40
60
80
N6
N5
N4
N3
N2
N1
MOUNTING
HEIGHT
UNIT SEPARATION
FEET
METERS
100
200
300
350
0
15
30
45
60
75
90
105
Содержание MPS-4100