Relay output wiring
2 - 14 • • • MPS-4100 product guide
Receiver features
Velocity response
The MPS-4100 has two jumper-selectable target speeds, Slow and Fast. The
default setting is the slow target speed, which is used for detecting human
intruders. The fast target speed is used in situations where only vehicles must be
Feature
Function
Feature
Function
LD1
Jam - Receiving interference no
detection
TB1
Receiver I/O connections - Audio O/P,
Power I/P, Self-test I/P (relay)/data I/O
(MPS-4100), Tamper O/P, Alarm O/P
LD2 to LD11
Alignment aid LEDs - visual indication of
received signal strength (S2-4 ON
enables LEDs; OFF disables LEDs)
TB2
Mate Transmitter interconnection -
Tamper I/P from Tx, Power O/P to Tx
LD12
Wrong channel - Tx and Rx modulation
frequency settings do not match
TB3
Slave system interconnect - 2 common
terminals (COM = gnd), Alarm 2
(Alarm O/P from slave), Tamper
(Tamper O/P from slave), Test 2 (self-
test O/P to slave), Audio 2 (Audio O/P
from slave)
LD13
Alarm - ON indicates alarm condition
JP1/JP2
Modulation frequency selection
jumpers - both jumpers must be set to
the same channel as the mate
transmitter
TP6/TP12
Alignment aid - connect voltmeter
(TP6 = +, TP12 = gnd) to get a voltage
reading of the received signal strength
(0 to 5 V range; >3.5 V = OK)
JP3
Receiver tamper relay setting - NO =
normally open, NC = normally closed
Local Audio
1/8 in. headphone jack - audio
assessment of microwave field
disturbance
JP4
Tamper relay supervision selection - 3K
= on-board 3 k
Ω
series EOL supervision
(requires NC setting on JP3), NO 3K =
no supervision resistor
S1
Receiver configuration DIP-switch (see
Table 2-4 for details)
JP5
Receiver alarm relay setting - NO =
normally open, NC = normally closed
S2
Receiver configuration DIP-switch (see
Table 2-4 for details)
JP6
Alarm relay supervision selection - 3K
= on-board 3 k
Ω
series EOL supervision
(requires NC setting on JP5), NO 3K =
no supervision resistor
RV1
Sensitivity adjustment POT - clockwise
to increase microwave sensitivity;
counter-clockwise to decrease
JP7
Microwave response selection - Fast
setting used for vehicles -
25 cm/s to 61 m/s (10 in./s to 200 ft./s);
Slow setting used for human intruders -
5 cm/s to 13.4 m/s (2 in./s to 44 ft./s)
(default setting = Slow)
RV2
Alarm relay duration POT - set the
period for which the alarm relay will
remain active following an event, max.
2.5 sec., min. 0.5 sec., default = 1.5 sec.
Tamper Switch
Two position plunger - held down by
enclosure cover = secure state;
enclosure opened = alarm state; pull
out plunger to over-ride tamper for
servicing unit
P1
Polarized 21-pin header for the connection of a Communication Interface Card
Table 2-3 Receiver features