Network wiring (Silver/StarNeT 1000)
2 - 24 • • • MPS-4100 product guide
Wiring the Receiver for Silver/StarNeT 1000
Single Zone
For single zone network operation, install the terminal block included in kit
E6KT0200 on TB3 and terminate with 3k
Ω
resistors (see Figure 2-19).
Dual Zone (Host/Slave configuration)
The first MPS-4100 Receiver/Transmitter pair is designated as the Host system.
The second MPS-4100 Receiver/Transmitter pair is designated as the Slave system.
The Host Receiver includes the Communications Interface Card, which connects
to the network. The Slave Receiver wires to the Host receiver.
Setup all tamper and alarm relays as NC with 3 k
Ω
resistor
supervision.
Depending on the Transmitter powering and tamper reporting scheme being
used there are two options for Transmitter tamper wiring.
•
The Host Transmitter wires to the Host Receiver, the Slave Transmitter wires
to the Slave Receiver.
•
The switched power Transmitter tamper reporting option (no tamper wiring).
Figure 2-20 Master/Slave connection diagram
CH6
CH5
CH4
CH3
CH2
CH1
JP1
S1
ON
6 5
1
2
4 3
OFF
TMPR
PWR
TB1
+
MPS-4100
Microwave Transmitter
SLAVE
PWR
LED
CH6
CH5
CH4
CH3
CH2
CH1
JP1
S1
ON
6 5
1
2
4 3
OFF
TMPR
PWR
TB1
+
PWR
LED
MPS-4100
Microwave Transmitter
HOST
XMTTR
CONNECT
TMPR
PWR
COM
ALM 2
TMPR
TEST 2
COM
AUD 2
TB3
AUD PWR
DATA/
TEST TMP ALM
TB1
CH6
CH5
CH4
CH3
CH2
CH1
JP1 JP2
P1
S1
ON
OFF
TB2
S2
ON
OFF
+
+
+
+
6
12 4
3 5
MPS-4100
Microwave Receiver
SLAVE
XMTTR
CONNECT
TMPR
PWR
COM
ALM 2
TMPR
TEST 2
COM
AUD 2
TB3
AUD PWR
DATA/
TEST TMP ALM
TB1
CH6
CH5
CH4
CH3
CH2
CH1
JP1 JP2
P1
S1
ON
OFF
TB2
S2
ON
OFF
+
+
+
+
6
12 4
3 5
MPS-4100
Microwave Receiver
HOST
E6BA01__ ___
REV __
POWER
TX A
RX A
FAULT A
RESERVE
TX B
RX B
FAULT B
ALARM 1
ALARM 2
SUPERVISION 1
SUPERVISON 2
AUDIO SEL 1
AUDIO SEL 2
SELF TEST 1
SELF TEST 2
S2
ON
ON
J2
TB2
TB1
J1
S1
00-003
12 to 24 VDC
Comm A from
previous master RX
Comm B to
next master RX
Communication Interface Card
required in each Host Receiver
+
Communication Interface Card NOT
required in Slave Receiver (Slave unit
communicates through Host)
Содержание MPS-4100
Страница 1: ...Product MPS 4100 Microwave Protection System Guide E6DA0102 003 Rev C Third Edition April 27 2009 ...
Страница 6: ......
Страница 70: ......