Relay output wiring
2 - 10 • • • MPS-4100 product guide
Relay output wiring
MPS-4100 Transmitter wiring
1. Connect the power and tamper wires to TB1 (see Figure 2-7). Power may
come from a power supply, or from TB2 on the Receiver.
Observe polarity
.
2. Set the modulation frequency to the desired channel (1 through 6) via JP1.
The Transmitter modulation frequency must match the Receiver
modulation frequency.
3. Configure the Tamper notification for conventional relay output or switched
power (see Figure 2-8).
Figure 2-7 MPS-4100 Transmitter connections
To Receiver TB2
OR
Alarm annunciator
12 to 24 VDC from
Receiver TB2
OR
power supply
Transmitter tamper
configuration
Modulation frequency
selection jumpers
(MUST match Receiver)
+VDC
- VDC
CH6
CH5
CH4
CH3
CH2
CH1
JP1
S1
ON
6 5
1
2
4 3
OFF
TMPR
PWR
TB1
+
MPS-4100
Microwave Transmitter
PWR
LED