Network wiring (Silver/StarNeT 1000)
2 - 20 • • • MPS-4100 product guide
Setting the network device address
Each Silver or StarNeT 1000 network device requires a unique address. Refer to
the site plan to determine the network device address assigned to the MPS-4100
Microwave system. For the Silver Network, the address must be between 1 and 32.
For StarNeT 1000 the address must be between 0 and 127. The address is set on
DIP-switch S1 (see Figure 2-14).
Setting the baud rate
All network devices on a Crossfire network (StarNet 1000) must communicate at
the same baud rate (typically 19.2 k). Refer to the site plan for the Crossfire baud
rate and set the baud rate via S2 on the Communications Interface Card (see
Figure 2-15). All Silver Network based devices communicate at a fixed baud rate of
57.6 k (the Silver Network baud rate cannot be adjusted).
Figure 2-14 Network device address settings
Figure 2-15 Baud rate settings
SW1 - device address
Silver 1 - 32
StarNeT 0 - 127
network type
OFF = Silver
ON = StarNeT
address
1
2
3
4
5
6
7
0
1
2
3
4
l
8
l
16
l
32
l
64
l
126
127
OFF OFF OFF OFF OFF OFF OFF
ON OFF OFF OFF OFF OFF OFF
OFF ON OFF OFF OFF OFF OFF
ON ON OFF OFF OFF OFF OFF
OFF OFF ON OFF OFF OFF OFF
| | | | | | |
OFF OFF OFF ON OFF OFF OFF
| | | | | | |
OFF OFF OFF OFF ON OFF OFF
| | | | | | |
OFF OFF OFF OFF OFF ON OFF
| | | | | | |
OFF OFF OFF OFF OFF OFF ON
| | | | | | |
OFF ON ON ON ON ON ON
ON ON ON ON ON ON ON
switch position
set address
switch setting for
Silver Network address 1
ON
S1
12
34
567
8
S1 - baud rate/LED power
S1, S2
set baud rate
S4
LED power
ON = LEDs ON
OFF = LEDs OFF
baud rate switch setting
2400
4800
9600
19200
1 2
ON ON
OFF ON
ON OFF
OFF OFF
ON
S2
1234
S3
N/A
switch setting illustrates
baud rate = 19200
LED power ON