Network wiring (Silver/StarNeT 1000)
MPS-4100 product guide • • • 2 - 23
Setting up the MPS-4100 Receiver card
The Receiver card requires shunt and DIP-switch adjustments to communicate on
the Silver or StarNeT 1000 networks. The following procedure applies to single
system MPS-4100 microwaves, which are connected to Silver Networks or StarNeT
1000 systems. For dual systems, refer to Figure 2-12 for information about Host/
Slave setup.
1. Install a shunt on JP4, pins 2-3 (3 K position).
2. Set DIP-switch S1 as follows:
3. Set DIP-switch S2 as follows:
Figure 2-19 Receiver setup for Silver Network/StarNeT 1000 (single system)
SWITCH
1
2
3
4
5
6
POSITION
ON
OFF
ON
OFF
ON
ON
SWITCH
1
2
3
4
5
6
POSITION
OFF
OFF
ON
ON
ON
OFF
install terminal block
and 3 k resistors on
TB3 for single systems
and on Slave Receivers
setup alarm
& tamper relays
as NC 3k Ohm
supervision
(JP3, JP4, JP5, JP6)
install MPS-4100
Communications
Interface Card
on P1
set DIP-switches
S1 and S2
switch ON =
1
S1
S2
JP4
JP6
JP5
JP3
JP1
JP2
S3
TAMPER SW
Slave
connect
ALARM
JAM
WRONG
CHANNEL
ALIGNMENT
AID LEDs
CH6
CH5
CH4
CH3
CH2
CH1
LOCAL
AUDIO
sensitivity
JP7
3K
no 3K
NC
NO
NC NO
FAST SLOW
POOR
BETTER
BEST
TAMPER
ALARM
TP6
TP5
TAMPER
RV3
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
ON
OFF
RV2
3K
no 3K
alarm
duration
RV1
TP12
LD12
LD1
LD13
LD11
LD2
MPS-4100
Microwave Receiver
COM
ALM 2
TMPR
TEST 2
COM
AUD 2
TB3
AUD PWR
DATA/
TEST TMP ALM
TB1
+
+
+
XMTTR
CONNECT
TMPR
PWR
TB2
+
P1