Relay output wiring
2 - 16 • • • MPS-4100 product guide
Receiver DIP-switch settings
Definition of Receiver DIP-switch functions
Network operation:
Enables network communication via plug-in communication
interface card.
Relay output operation:
Enables relay output for alarm and tamper.
Self-test enable:
Enables a self test upon 12 VDC input. Relay version only. Must be
OFF for network operation.
Alarm on jam:
Triggers an alarm output upon JAM condition.
Tamper enable for network operation:
Enables tamper signal for network
operation. Must be off for relay output operation.
Slave Audio:
Enables audio output via TB3. Must be ON for slave Receiver audio.
Alignment LED Enable:
Enables Alignment Aid LED’s. Disable after alignment for
reduced power consumption.
Alarm Relay Reset:
Enables reset of alarm relay. In OFF position, alarm relay
latches following alarm until reset manually. (Toggle S2-5 to reset alarm relay.)
Alarm Relay Enable:
Enables alarm relay operation for relay output version. May
be turned OFF for network operation if local alarm annunciation is not required.
Figure 2-12 MPS-4100 Receiver configuration options
5 6
OPEN
CLOSED
1 2 3 4
CLOSED =
5 6
OPEN
CLOSED
1 2 3 4
5 6
OPEN
CLOSED
1 2 3 4
5 6
OPEN
CLOSED
1 2 3 4
5 6
OPEN
CLOSED
1 2 3 4
5 6
OPEN
CLOSED
1 2 3 4
5 6
OPEN
CLOSED
1 2 3 4
5 6
OPEN
CLOSED
1 2 3 4
= ON
For StarNeT 1000 network communications, 3.3 K termination resistors must be installed at TB3.
*
Typical switch settings - Standalone or Slave receiver relay output
Typical switch settings - Network output
*
*
S1
S2
S1
S2
S1
S2
S1
S2
Single system
Single system
Dual zone - Host system
Dual zone - Slave system
OPEN =
= OFF
Содержание MPS-4100
Страница 1: ...Product MPS 4100 Microwave Protection System Guide E6DA0102 003 Rev C Third Edition April 27 2009 ...
Страница 6: ......
Страница 70: ......