Network wiring (Silver/StarNeT 1000)
MPS-4100 product guide • • • 2 - 17
Network wiring (Silver/StarNeT 1000)
Communication Interface Card
The optional MPS-4100 Communication Interface Card (P/N E6BA010X-003)
enables the MPS-4100 Microwave system to communicate via the Silver Network
or the StarNeT 1000 network. Installed on header P1 on the MPS-4100 Receiver
unit PCB, the card provides redundant network communications through two
separate channels (A and B).
Figure 2-13 Communication Interface Card
E6BA01__ ___
REV __
POWER
TX A
RX A
FAULT A
RESERVE
TX B
RX B
FAULT B
ALARM 1
ALARM 2
SUPERVISION 1
SUPERVISON 2
AUDIO SEL 2
AUDIO SEL 1
SELF TEST 1
SELF TEST 2
S2
ON
ON
J2
TB2
TB1
J1
S1
polarizing plug - pin 8
status LEDs
J2 (transponder connect)
connect to P1 on Receiver
TB2
A-side EIA-422 connection
TB1
B-side EIA-422 connection
J1 (firmware update)
S1
sw1 to sw7 - address select
sw8 - network type select
S2
sw1, sw2 - baud rate (StarNeT 1000)
sw4 - LED control
sw3 - not used
TXA
RXA
TXB
RXB
TXB
RXB
TXA+
TXA-
RXA+
RXA-
GND
TXB+
TXB-
RXB+
RXB-
GND
TXA+
TXA-
RXA+
RXA-
GND
NIC variants:
E6BA0100-003 - EIA-422
E6BA0101-003 - multimode Fiber Optic
E6BA0102-003 - EIA-422/mmFO
00-003
E6BA0101-003
E6BA0102-003
Содержание MPS-4100
Страница 1: ...Product MPS 4100 Microwave Protection System Guide E6DA0102 003 Rev C Third Edition April 27 2009 ...
Страница 6: ......
Страница 70: ......