92
Step 3: ETM® System Configuration
6.
In the
Signal Type
column, for each enabled channel, click the down
arrow and select the correct signaling in use on the channel.
CAUTION
If
Signal Type
is set incorrectly, the Span will not be
able to evaluate Policy Rules against calls or terminate calls.
To specify the same signal type for all channels (or an adjoining
group of channels), click the first
Signal Type
cell, hold down
SHIFT, and then click the last cell, and then click the down arrow
in the last selected cell and select the signaling type.
The following signal types are supported:
–
WINK (T1 CAS)
–
GROUND (T1 CAS, Analog)
–
LOOP (T1 CAS, Analog)
–
IMMEDIATE (T1 CAS, Analog)
–
ISDN PRI (E1 and T1 PRI)
–
WINK IN/IMMEDIATE OUT (T1 CAS)
–
IMMEDIATE IN /WINK OUT (T1 CAS)
–
R1 (E1 CAS)
7.
(Optional)
In the
Trunk Group
column, click a cell and type the trunk
group for the channel. A trunk group entry can contain a maximum of
20 characters.
To specify the same trunk group for an adjoining group of
channels, click the first
Trunk Group
cell, hold down SHIFT,
and then click the last cell, and then type the trunk group. When
you click anywhere else on the dialog box, the trunk group is
applied to all of the cells you had selected.
8.
The
Caller ID
field indicates whether Caller ID is enabled on a channel
and should be used to determine calling numbers. If a Caller ID option
is not selected, Caller ID is not used, even if it is available on the line.
Note that if you specify Caller ID for a channel on which Caller ID is
not actually available, error messages appear in the
Caller ID
field of
the call log.
If Caller ID is available in the call data, in the
Caller ID
column, click
the drop-down box and select the type of Caller ID for each enabled
channel. The default is
None
. The following options are available:
Bellcore
—US, Canada, South Korea
UK BT
—British Telecom users in the UK
ETSI
—UK, Germany, Italy
To place the same value
in a contiguous set of
fields, click the first field,
hold down SHIFT, click
the last field, and then
click the down arrow in
the last field and select
an option.