Removing and Replacing Appliance Components
193
14.
Confirm that each Span is monitoring calls by viewing call activity in
the
Call Monitor
. Verify that phone numbers in the
Call Monitor
are
correctly displayed. If not, verify that the correct Dialing Plans were
installed in Step 10 and that those Dialing Plans are correctly
configured.
15.
When proper operation has been confirmed, remove the old Card icon
from the
Platform Configuration
subtree.
To remove the Card icon, right-click the icon, and then click
Edit
Card(s)
. In the
Card Configuration
dialog box, click
Remove
.
16.
Follow the shipping instructions provided with the new Card to return
the old Card to SecureLogix.
In the ETM 3200 Appliance, if one of the power supplies fails, the second
power supply can temporarily handle the load while you replace the failed
unit. You can also quickly power off a DC Appliance by pulling both power
supplies. You can remove and replace a power supply without powering off
the chassis.
To remove and replace a power supply
1.
Remove the screws securing the failed power supply to the chassis.
2.
Flip up the black latch and pull the power supply out from the chassis.
3.
Insert the new power supply into the chassis, aligning the power supply
connector with the chassis power supply connector.
4.
Flip the latch down and insert the screws to secure the power supply to
the chassis.
5.
Verify that the Power LED on the front of the power supply is
illuminated.
Removing and
Replacing a
Power Supply