206
Appendix E: Appliance Status LEDs
The table below identifies the types of information, errors, and warnings
represented by the LEDs on the ETM 1060 Appliance.
Error
Front
Off during normal operation with no errors detected
and the
Status
LED blinking green.
Red LED indicates:
–
Card temperature above 70 degrees C
–
Card in fail safe mode
–
Power supply failure
–
Fan unit failure
Yellow blinking LED can indicate an error in one or more of the following:
–
Dialing Plan:
File access error
Allocation error
Bad range or entry in file
Range start greater than range end
Unknown file name
Algorithm ID out of range, no match string, or no substitution string
(DID)
–
Management Server interface:
Initially set to indicate Card/Server socket is not established
Loss of Server socket connection
–
Cabinet/Card temperature above 60 degrees C
Status
Front
Green and blinking, with
Error
LED off:
–
Dialing Plan read/parsed successfully
–
Call Recorder Policy read/parsed successfully
–
Management Server Server-socket connection established
–
No Telco Alarms
–
Cabinet temperature below 60 degrees C
I/F
Front
Green indicates that the Digital Trunk Interface is operational
Red indicates that the Digital Trunk Interface has an error.
PMC
Front
Off if the DSP Mezzanine Card is not present.
Green indicates that the DSP Mezzanine Card is operational.
Red indicates that the DSP Mezzanine Card has an error.
1060 Appliance
LEDs