Install the Appliances
53
AC Appliances are supplied with a power cord.
To connect power to an AC Appliance
1.
Connect the receptacle end of the provided power cord to the
Appliance.
2.
Plug the power cord provided with your Appliance into a 100-
240VAC, 50-60Hz power source that is protected by a 15-amp circuit
breaker or fuse.
3.
Press the Appliance power switch to the
On
position.
4.
Observe that the fans are running and that LEDs are illuminated. For
information about each of the LEDs on the Appliance(s), see "LED
Descriptions" on page 203.
The DC version of the ETM 3200 Appliance requires -36VDC to -72VDC
at 7.9A. Since customer-premises equipment varies, a wire harness is not
provided.
To connect power to a DC Appliance
1.
Connect the wire harness to the -48V and RTN terminals at the rear of
the Appliance.
2.
With power disconnected from the power source, connect the wire
harness to a -36 to -72VDC, 7.9A power supply that is protected by a
9.5-amp circuit breaker or fuse.
3.
Connect power to the power source. (For example, insert a fuse into the
fuse panel position assigned to the Appliance.) The DC Appliance has
no power switch.
4.
Observe that the fans are running and that LEDs are illuminated. For
information about each of the LEDs on the Appliance(s), see "LED
Descriptions" on page 203.
On the back of the AAA Server, two or four modem ports are provided for
connection to telephone lines.
To connect telephone lines to the AAA Server modem(s)
Using a standard telephone line cord with an RJ-11 connector, plug a
telephone line into one or more ports on the back of the AAA Server.
AC Appliances
DC Appliances
(AAA Only)
Connect the
Modem Line(s)