Replacing an HS Expander module
85
Replacing an HS Expander module
This section provides procedures for replacing a failed HS Expander module. Illustrations in HS Expander replacement
procedures show top panel views of the enclosure, with the module properly oriented for insertion into the top panel of
the enclosure near the right wall.
If an HS Expander module fails, the remaining modules are sufficient to maintain operation of the enclosure. You need
not halt operations and completely power-off the enclosure when replacing only one HS Expander module.
See CAUTION bullets regarding
electrostatic discharge
and
anti-static protection
on
.
TIP:
The illustrations show HS Expander module replacement as you face the enclosure front and view the top panel.
See also
Removing an HS Expander module
CAUTION:
Removing this hot-swappable PCBA disrupts the enclosure’s airflow. Do not remove the PCBA until you
have received the replacement. It is important that all FRU module slots are filled when the enclosure is in operation.
1.
Open the respective half of the main bay cover
A
under which faulty expander lies.
2.
On the faulty HS Expander, grasp each of the two plastic swing-arms between thumb and index finger as shown in
.
Figure 68 Removing a HS Expander (1 of 2)