34
–
4.
INSTALLAZIONE • INSTALLATION
ENGLISH
ITALIANO
19
A
B
040_074_0.tif
20
L1 L2 L3
A
18
Prearrange the feeding cable near
the terminal board
A
(fi g. 18).
– Connect the cables to the termi-
nals
L1-L2-L3
of the socket and
the earthing cable to the terminal
marked by the
ymbol ;
– connect socket
A
to plug
B
(fi g. 19).
CAREFUL WITH THE ELECTRICAL
CONNECTION
Incorrect rotation of the tool
causes danger to the operator and
damage to the product.
Activate the saw assembly for a
fraction of a second and check
that the disc turns clockwise.
Should rotation be incorrect,
immediately switch off the power
and invert two of the three phases
on the terminals (L).
Predisporre il cavo di alimenta-
zione in prossimità della presa
A
(fi g. 18) in dotazione.
– Collegare i cavi di alimentazione
ai morsetti
L1
-
L2
-
L3
della presa
in dotazione, e il cavo di terra al
morsetto contrassegnato con il
simbol
;
– connettere la presa
A
alla spina
B
(fi g. 19).
ATTENZIONE AL
COLLEGAMENTO ELETTRICO
L'errata rotazione dell'utensile
causa pericolo all'operatore e
danni al prodotto.
Avviare per una frazione di
secondo il gruppo sega e
verifi care che il disco ruoti in
senso orario; nel caso la rotazione
non sia corretta, togliere
immediatamente tensione ed
invertire due delle tre fasi sui
morsetti (L).