189
While in the two-port connection in AEP mode, this port can be used for both receiving print data and
returning the product status.
The setting range is from 1 to 65535.
•
Set different values for each port (1, 2, and 3).
•
Set a value other than 20, 21, 22, 53, 80, 123, 443, 465, 515, 546, 547, 587, 8080,
or 8883. These values duplicate other port numbers, so that correct communications
would be impossible.
•
You can change the return status format of Port3 to compatible mode by enabling
[Legacy Status for Port 9100].
•
AEP does not support STATUS3, STATUS4, or STATUS5.
[Flow Control]
Set the communication protocol.
The options are as follows:
•
[STATUS4]
•
[STATUS4 ENQ]
•
[STATUS3]
•
[STATUS5]
•
[NONE]
[TCP Connection Queue]
Set whether to allow queuing for connection when multiple hosts or applications are sending
connection requests to the product.
While connecting with one host or application, the product can receive connection requests from
other hosts or applications. The subsequent connection requests are put on hold, and processed
in order of reception after the first connection is closed.
While connecting with one host or application, the product cannot receive connection requests
from other hosts or applications.
•
When you have enabled the setting, be sure to use one port connection for STATUS3,
STATUS4, and STATUS5. Operation using two port connections for STATUS4 is not
guaranteed.
[Legacy Status for Port 9100]
Set whether to change the return status format of Port3 to compatible mode.
Does not appear if you have selected [NONE] in the [Flow Control] menu.
In compatible mode, the return status format of Port3 becomes as follows:
STATUS3
Содержание CT4-LX
Страница 1: ...FX3 LX...
Страница 37: ...37 Quickly brush your finger up down left or right against the screen...
Страница 51: ...51 3 Tap The print job is canceled...
Страница 190: ...Network 190 Compatible mode Standard mode STATUS4 Compatible mode Standard mode STATUS5 Compatible mode...
Страница 254: ...Theme 254 The options are as follows Soft Gray Dark...
Страница 286: ...Flow Control 286 Flow Control Set the communication protocol The options are as follows STATUS3 STATUS4 MULTI NONE...
Страница 294: ...Wi Fi Setting 294 Compatible mode Standard mode STATUS4 Compatible mode Standard mode STATUS5 Compatible mode...
Страница 312: ...Media Sensor Positions and Media Stop Positions 312 15 Feed direction...
Страница 317: ...317 Timing Chart When TW is 10...
Страница 319: ...319 Timing Chart When TW is 10...
Страница 327: ...327 Timing Chart...
Страница 329: ...329 Timing Chart...
Страница 361: ...361 Tear Off Mode When the Top Cover Is Closed and There Is a Label Above the Label Top Sensor...
Страница 362: ...362 Tear Off Mode When the Top Cover Is Closed and There Is No Label Above the Label Top Sensor...
Страница 365: ...365 Cutter Mode and Backfeed After Printing When the Top Cover Is Closed and There Is a Label Above the Label Top Sensor...
Страница 369: ...369 Linerless Tearoff Mode I mark Linerless Label 1 Feed direction 2 Tear off position 3 Print position...
Страница 389: ...389 5 Tap Write Power 6 Set the writing power and then tap Keep the setting value up to 24 dBm 7 Tap Read Power...
Страница 394: ...Loading the Saved RFID Tag Model 394 3 Tap Load 4 Tap the RFID tag model to load 5 Tap on the confirmation screen...
Страница 462: ...462 Contact your SATO technical support if the error cannot be resolved Contact Information for When You Are in Trouble...
Страница 471: ...471 Contact your SATO technical support if the error cannot be resolved Contact Information for When You Are in Trouble...
Страница 556: ...556 Scalable Fonts The product contains various scalable fonts The figure below is a sample of some scalable fonts...
Страница 564: ...Back Cover June 2020 Version 3...