MMC 852 (Page 1 of 1)
MMC: 852
ASSIGN SYSTEM
ALARMS
FOR:
i
DCS100
i
DCS500
OS500
(
i
DCS systems must have a LAN interface installed.)
Purpose:
Assigns system alarms to ring and display on stations that have a System
Alarm key programmed in
. System Alarm key programming is tenant-wide on
i
DCS500 and OS500 systems (tenants 1 and 2). Alarms not programmed to report to the
System Alarm key will still be retained in the maintenance alarm buffer for alarm report-
ing (
). The alarm buffer holds up to 100 alarms on a First In/First Out (FIFO)
basis. Pressing the System Alarm key will silence the audible alarm until another alarm is
generated by the system. Alarm conditions that have multiple causes (e.g. E1 errors and
synchronization loss) will print all associated alarm information if an SIO port is pro-
grammed as an ALARM port in
. The specific fault alarm data can be displayed
via MMC 851.
Note: Alarm Notification Off/On (0/1) determines if the alarm provides a visual and audible notifi-
cation to the System Alarm key station(s). Pressing the System Alarm key and the ANS/RLS key
will silence the audible alarm only at the station at which these keys were pressed.
Refer to the Alarm Code Table in
. Codes MJA01 to MNF27 are designated
numbers 01–87 respectively in MMC 852, and each is selectable ON/OFF.
ACTION
DISPLAY
1. Open programming and select
852
Display shows
01:MJA01 ACT:OFF
POR Restart
2. Press VOLUME keys to select alarm number and
press RIGHT soft key
01:MJA01 ACT:OFF
POR Restart
3. Press VOLUME keys to select alarm ON/OFF (e.g.
ON) and press RIGHT soft key
01:MJA01 ACT:ON
POR Restart
4. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data:
All alarms OFF
Related Items
MMC 501 System Timers
MMC 722 Station Key Programming
MMC 723 System Key Programming
MMC 851 Alarm Report
MMC 853 Maintenance Busy