SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 504 (Page 1 of 1)
MMC: 504
PULSE MAKE/BREAK RATIO
FOR: DCS CII
816
408
i
DCS100
i
DCS500
OS500
Purpose:
Allows the value of pulses per second and the duration of the make/break time
to be changed. This only affects rotary dial trunks.
FEATURE KEYS
Dial 0
Make/Break ratio (01–99)
Dial 1
Pulse Per Second (10 or 20)
ACTION
DISPLAY
1. Open programming and select
504
Display shows
MAKE/BREAK RATIO
33 MAKE
→
2. Dial 0 or 1 for option (e.g. 1)
OR
Press VOLUME keys for selection and press
RIGHT soft key to move cursor
PULSE PER SECOND
10 PPS
→
_
3. Dial in new value (e.g. 20)
System returns to step 2
PULSE PER SECOND
10 PPS
→
20
4. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next MMC
Default Data:
Make/Break = 33
Pulses Per Second = 10
Related Items:
MMC 402 Trunk Dial Type