SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 851 (Page 4 of 5)
ALM CODE
ALARM
DEFINITION
MJD09
Bit Error Alarm
Alarm is activated when the when error rate exceeds 1x10-6 er-
rors. Note: 1x10-6 is threshold for minor alarm; 1 x 10-3 is
threshold for major alarm errors on E1, PRI or BRI.
Alarm Data = Cabinet, Slot (Cx-Syy)
MJD10 NTWRK
Event
An Implausible event has occurred on the PRI or BRI Network
digital line. Protocols do not match or subscriber ID mismatch.
Alarm Data = Cabinet, Slot (Cx-Syy)
MJD11
SPID Init Error
The BRI received an error from the network
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
MJD12
SPID Init Rec
The BRI has recovered from an error on the network
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
MJD13 LPBK
Error
Internal on-demand loopback failed.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
MJD14 LPBK
Recovery
Internal on-demand loopback test passed.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
MJD15
BRI DL Unavail
A BRI data link is out of service.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
MJD16
BRI DL Recovery
A BRI data link is back in service.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
MJD17 RAM
Error
An error has occurred in the TEPRI or BRI card RAM.
Alarm Data = Cabinet, Slot (Cx-Syy)
MJD18 E1
Restart
The E1 card has restarted
Alarm Data = Cabinet, Slot (Cx-Syy)
MJD19 PRI
Restart
The PRI card has restarted
Alarm Data = Cabinet, Slot (Cx-Syy)
MJD20 BRI
Restart
The BRI card has restarted
Alarm Data = Cabinet, Slot (Cx-Syy)
MJD21 PCM
Loss
Loss of PCM coding on a digital facility.
Alarm Data = Cabinet, Slot (Cx-Syy)
MJD22 PCM
Recovery
Recovery of PCM coding on a digital facility.
Alarm Data = Cabinet, Slot (Cx-Syy)
MNF01 Card
Out
A circuit card mounted in a universal slot has been removed from
service or is not recognised by the system
Alarm Data = Cabinet,Slot (Cx-Syy)
MNF02 Card
In
A circuit card mounted in a universal slot has been returned to
service.
Alarm Data = Cabinet, Slot (Cx-Syy)
MNF03 IPC
Error
Inter processor communication error has occurred.
Alarm Data = Cabinet-Slot (Cx-Syy)
MNF04 Trunk
Fault
Out of service trunk detected via loop detect. Internal CODEC
test.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
MNF05 Trunk
Recovery
Out of service trunk detected via loop detected as out of service
is now operational.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)