SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 707 (Page 1 of 1)
MMC: 707
AUTHORISATION CODE
FOR:
ALL
SYSTEMS
Purpose:
Sets up authorisation codes on a per-class of service basis. The number of
codes (entries) allowed and the maximum number of digits per entry are shown in the
table.
DCS
CI / CII
816
408/408i
i
DCS100
i
DCS500
‘M’
i
DCS500
‘L’
OS500
No. of
entries
250
(001–250)
100
(001–200)
30
(01–30)
10
(01–10)
250
(001–250)
250
(001–250)
500
(001–500)
500
(001–500)
No. of
digits
4 4 4 4 4 4
4–10
4–10
ACTION
DISPLAY
1. Open programming and select
707
Display shows
AUTHOR.CODE(001)
CODE: COS:01
2. Dial code entry number (see above) including any
leading zeros (e.g., 05 or 005)
OR
Press VOLUME keys to selected index number
and press RIGHT soft key to move cursor
AUTHOR.CODE(005)
CODE:_ COS:01
3. Enter authorisation code (e.g., 1234) and press
RIGHT soft key to move cursor
AUTHOR.CODE(005)
CODE:1234 COS:01
4. Enter class of service number 01–30 (e.g., 05)
OR
Press VOLUME keys to select COS and press
RIGHT soft key to select and return to step 2
AUTHOR.CODE(005)
CODE:1234 COS:05
5. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data:
None
Related Items:
MMC 305 Assign Forced Code