SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 605 (Page 1 of 1)
MMC: 605
ASSIGN EXTERNAL
PAGE ZONE
FOR:
ALL
SYSTEMS
Purpose:
Determines which relays will close when one of the external page zones 5 to 8
is accessed. (816 and 408/408i systems have only one external page zone—see below.)
DCS
System must be equipped with a Trunk A card to allow external paging. Each
Trunk A card is equipped with two external page relays. The page relays have
default DNs of 360X (e.g. 3601)
CII
One external page zone is located on the base board. Three are located on
the optional MISC card. The page relays have default DNs of 36x (e.g. 361)
816/408/408i
One external page zone (zone 5) is located on the base board. The page re-
lay has a default DN of 361. The optional port is 362 (see
i
DCS100
One external page zone is located on the base board. Three are located on
the optional MISC card. The page relays have default DNs of 36x (e.g. 361)
i
DCS500
System must be equipped with a MISC card for external paging
OS500
System must be equipped with a MISC card for external paging
ACTION
DISPLAY
1. Open programming and select
605
Display shows first page zone (member number
shows as 1 or 01 etc, depending on system)
EXT. PAGE ZONE:(5)
MEMBER 1 :NONE
2. Dial page zone number (e.g., 6)
OR
Press VOLUME keys to select desired page zone
number and press RIGHT soft key to move cursor
EXT. PAGE ZONE:(6)
MEMBER 1 :NONE
3. Dial member number (e.g., 3 or 03)
OR
Press VOLUME keys to select member number
and press RIGHT soft key to move cursor
OR
Press LEFT soft key to return to step 2
EXT. PAGE ZONE:(6)
MEMBER 3 :NONE
4. Dial relay number (e.g., 362 or 3602) and press
RIGHT soft key to return to step 2
OR
Press LEFT soft key to return to step 3
EXT. PAGE ZONE:(6)
MEMBER 3:362
5. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next MMC
Default Data:
None
Related Items:
MMC 219 Common Relay Service Type