SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 851 (Page 5 of 5)
ALM CODE
ALARM
DEFINITION
MNF06 Trunk
Disconnect
Out of service trunk detected via seizure of trunk. External
seizure test.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
MNF07 Trunk
Connect
Out of service trunk recovered via seizure of trunk External
seizure test.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
MNF08
SIO TxQ Over
SIO Tx Queue full error has occurred in the MCP.
Alarm Data = SIO number (SIO:x)
MNF09
SIO TxQ Under
SIO Tx Queue under error has occurred in the MCP.
Alarm Data = SIO number (SIO:x)
MNF10
E1 Out Of Srv
E1 Digital line status has been changed to out of service.
Alarm Data = Cabinet, Slot (Cx-Syy)
MNF11
E1 In Service
E1 Digital line has been restored to normal service.
Alarm Data = Cabinet,Slot (Cx-Syy)
MNF12 SIO
Out
IO port has lost DTR
Alarm Data = SIO number (SIO:x)
MNF13 SIO
In
IO port has regained DTR.
Alarm Data = SIO 1 through 3
MNF14
TODC Error
Time of Day Clock in the MCP in error.
MNF15
TSW Over Alarm
TSW has been requested to exceed the capacity of available
time slots. Maximum 192 per cabinet.
Alarm Data = Cabinet, Slot (Cx-Syy)
MNF16 PSU
Alarm
Indicates there are over 56 ports in a cabinet with a single PSU
and more power is required.
Alarm Data = Cabinet, Slot (Cx-Syy)
MNF17
PSU Alarm Rec
A second PSU has been recognised when added after alarm
condition of:
Alarm Data = Cabinet, Slot (Cx-Syy)
MNF18 SLI
Fault
An SLI card has been detected as out of service via an internal
CODEC test.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
MNF19 SLI
Recovery
An SLI card detected as out of service has been detected as
recovered and is in service via internal CODEC test.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
MNF20 PSUB
Alarm
Indicates there are over 120 ports in a cabinet with two PSUs.
Alarm Data = Cabinet, Slot (Cx-Syy)
MNF21
DSS Alarm
System capacity of 64-button DSS modules has been exceeded.
MNF22 Phone
Disconnect
Indicates the keyset is disconnected.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
MNF23 Phone
Connect
Indicates the keyset is connected.
Alarm Data = Cabinet, Slot, Port (Cx-Syy-Pzz)
MNF24
NOT USED
FUTURE USE
MNF25
NOT USED
FUTURE USE
MNF26
SIO RxQ Over
SIO Rx Queue full error has occurred in the MCP.
Alarm Data = SIO number (SIO:x)
MNF27
SIO RxQ Under
SIO Rx Queue under error has occurred in the MCP.
Alarm Data = SIO number (SIO:x)