SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 834 (Page 3 of 4)
OS
500 MGI Card & Procedure
GATEWAY CALL ID
A numeric entry that identifies the system via the MGI connection.
Maximum entry is four digits.
H.323 FAST SETUP
Enables or disables the H.323 Fast Start call method.
CALLER ID TYPE
This option controls the calling party identification type. The type is
identical to that sent by the caller to be displayed.
TUNNELING
Sets whether to use the Q.931 signalling channel for H.245 signal-
ling instead of using a separate channel.
DEFAULT DIL NO.
Sets the call forward number for incoming calls that does not
include the dial digit.
CODEC AUTO NEGO
Sets whether to automatically change the CODEC to be used according to
the other party.
SIGNAL PORT
Sets the IP port number for H.323 signalling.
SEND CLIP TABLE
Sets the Caller Data Table number in
that will be sent as
the caller information when calling through the VoIP network.
Number in
is used when set as None.
INCOMING MODE
For VoIP incoming calls, sets whether to use the received Called
Party Number as is, or to follow
, or to use the destina-
tion specified for each C.O. line in
ALLOW GW CHECK
Enables Gateway IP check.
ACTION
DISPLAY
1. Open programming and select
834
Display shows
GATEWAY CALL ID
1234
2. Press VOLUME keys to select option (e.g. H.323
FAST SETUP) and press RIGHT soft key
H.323 FAST SETUP
ENABLE
3. Press VOLUME keys to select ENABLE/DISABLE
press RIGHT soft key
H.323 FAST SETUP
DISABLE
4. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data:
GATEWAY CALL ID: 1234
H.323 FAST SETUP: DISABLE
CALLER ID TYPE: ANI
TUNNELING: DISABLE
DEFAULT DIL NO: 5000 (OR 500)
CODEC AUTO NEGO: OFF
SIGNAL PORT: 10000
SEND CLIP TABLE: 1
INCOMING MODE: FOLLOW DID TRANS
ALLOW GW CHECK: DISABLE
Related Items:
VoIP MMCs