MMC 840 (Page 1 of 1)
MMC: 840
IP SET INFORMATION
FOR:
OS500
Purpose:
Sets the parameters for Internet Phones connected to the system.
Parameter
Description
Default
USER ID
ID used to confirm new connection of a registered phone.
None
USER PSWD
Password used to confirm new connection of a registered phone.
None
IP ADDRESS
The IP address of the IP phone.
0.0.0.0
MAC ADDR
The hardware address of the IP phone (read only).
FFFFFFFFFFFF
SIG PORT
Port number used for signalling between IP terminals and the sys-
tem (this is adjusted for traversing firewalls if necessary).
06000
VOICE PORT
Port number used for voice transmission between IP terminals and
the system (this is adjusted for traversing firewalls if necessary).
09000
IP TYPE
Type of IP address (0. PRIVATE, 1. PUBLIC).
PRIVATE
DSP TYPE
G.729A or G.711.
G.729A
PHONE TYPE
Type of IP phone (0. SAMSUNG, 1. SIP STANDARD).
SAMSUNG
REGIST CLR
Deletes the registered IP phone data.
None
FRAME CNT
Frame count (1–4 x10MS).
4x
JITTER BUF
Jitter buffer (1–9 x10MS).
9x
TOS FIELD
Type of service packets.
00000000
SW VERSION
Software version (read only).
S/W Version
SW UPGRADE
Software upgrade (read only).
S/W Version
ACTION
DISPLAY
1. Open programming and select
840
Display shows
[3201] USER ID
3201
2. Dial
phone
number
OR
Press VOLUME keys to select and press RIGHT
soft key
[3201] USER ID
3201
3. Press VOLUME keys to select option and press
RIGHT soft key
4. Enter data for selected option
5. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data: See table above
Related Items: None