SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 804 (Page 1 of 3)
MMC: 804
SYSTEM I/O PARAMETER
FOR:
ALL
SYSTEMS
Purpose:
Sets parameters for the system I/O ports to work with one of the following:
•
a personal computer (PC)
•
Station Message Detail Recording (SMDR)
•
UCD statistics report/periodic UCD information (except 408/408i)
•
Computer-Telephony—TSAPI—Interface (CTI)
System
No. of I/O Ports
DCS, CII, 816
Two ports (Ports 1 and 2)
408/408i
One port (Port 1)
i
DCS500
Up to five ports available on an
i
DCS500 with a LAN module. The fifth port is
used for internal modem control. If no LAN module is installed, three ports are
available and the third port is used for internal modem control.
i
DCS100
Up to three ports available on an
i
DCS100. Two are supplied on the MISC 1
or MISC 2 card and one on a MEM4 card.
OS500
Three ports (Ports 2, 3 and 5). Port 5 is used for internal modem control.
Use the tables below to customise I/O ports.
PARAMETER OPTIONS
Dial 0
Service
Type of Service
Dial 1
Baud Rate
Speed
Dial 2
Char Length
Character Length
Dial 3
Parity
Parity Bit
Dial 4
Retry Count
Number of Retries
Dial 5
Stop Bit
Stop Bit
Dial 6
Wait Time
Message Wait Time
Dial 7
DSR Check
DSR Check on/off (
all systems except DCS
)
or
SIM Pair
No. of the station connected to the Serial Interface Module
(SIM) (
DCS systems only
)
SERVICE TYPE
Each port can be set to one of the following service types. Note that the services available depend on
the type of system being programmed. No two ports can be programmed with the same service type.
Type
Description
PC-MMC PC
application
SMDR
SMDR report (call logging)
UCD REPT
UCD report on request by the supervisor,
or daily
UCD/SMDR
Both SMDR and UCD report will be gen-
erated
CTI
Dedicated Switch Link Interface
CTI/SMDR
CTI and SMDR
CTI/UCD
CTI and UCD
CTI/S/U
CTI, SMDR and UCD