Product Overview
Function
Specification
Output
Output voltage (
V
)
0~Input voltage
Output current (
A
)
Refer to
the rated value
Output power (
kW
)
Refer to
the rated value
Output frequency (
Hz
) 0~400Hz
Technical control
feature
Control mode
SVPWM (V/F control), SVC (Sensorless Vectorial Control)
Motor type
Asynchronous motor
Speed ratio
Asynchronous motor 1:100 (SVC)
Speed control accuracy
±0.2% (sensorless vector control)
Speed fluctuation
± 0.3% (sensorless vector control)
Torque response
<20ms (sensorless vector control)
Torque control accuracy
10%(sensorless vector control)
Starting torque
Asynchronous motor: 0.5Hz/150% (SVC)
Overload capability
Constant Torque Load:
150% of rated current: 1 minute
180% of rated current: 10 seconds
200% of rated current: 1 second
Variable Torque:
120% of rated current: 1 minute
Running control
feature
Frequency setting
Digital setting, analog setting, pulse frequency setting,
multi-step speed running setting, simple PLC setting, PID
setting, MODBUS communication setting.
Shift between the set combination and set channel.
Auto voltage adjustment
Keep a stable voltage automatically when the grid voltage
transients
Fault protection
Provide over 30 fault protection functions: overcurrent,
overvoltage, undervoltage, overheating, phase loss and
overload, etc.
Speed tracking
Restart the rotating motor smoothly
Note: This function is available for the inverters of 4kW
and above 4kW.
Peripheral
interface
Terminal analog input
resolution
≤
20mV
Terminal switch input
resolution
≤
2ms
Analog input
1 channels ( AI2) 0~10V/0~20mA and 1 channel (AI3)
-10~10V
Analog output
2 channels (AO1, AO2) 0~10V /0~20mA
Digital input
8 channels common input, max. frequency of 1kHz,
internal impedance of 3.3k
Ω
;
1 channel high speed input, max. frequency of 50kHz
Digital output
1 channel high speed pulse output, max. frequency of 50kHz
1 channel Y terminal open collector pole output
Relay output
2 channels programmable relay output
RO1A NO, RO1B NC, RO1C common terminal
RO2A NO, RO2B NC, RO2C common terminal
Contactor capability: 3A/AC250V,1A/DC30V
Содержание CV50-008-4F
Страница 1: ...USER MANUAL INVERTER CONTROLVIT CV50 ...
Страница 2: ......
Страница 84: ...84 144 Function Parameters ...
Страница 101: ...Fault Tracking 101 144 8 6 4 Undervoltage fault 8 6 5 Abnormal motor heat ...
Страница 102: ...102 144 Fault Tracking 8 6 6 Inverter overheating 8 6 7 Stall during the acceleration of the motor ...
Страница 131: ...Dimension Drawings Appendix B 131 144 18 5 30kW flange mounting 37 110kW flange mounting 132 200kW flange mounting ...
Страница 142: ... ...
Страница 143: ... ...