28
CFIP PhoeniX C Series TDM/IP Split Mount System Technical Description and Configuration Guide
•
Rev. 1.0
•
© SAF Tehnika JSC 2013
Management and configuration examples of CFIP-16E1/T1-EXT
The configuration and status of the module can be found in web GUI in Ports/EMM management
menu:
EMM SUPPORT
This check box changes mode of SFP2 port from standard Gigabit ETH to proprietary EMM (Expansion)
mode. When EMM mode is enabled by this checkbox, IDU starts communication with all connected
EMM expansion modules.
EMM SETTING
–
EMM Type
- displays the type of connected EMM (Expansion) card.
-
N/A
- indicates that particular position is empty;
-
RELAY-IDU
- indicates that the relay IDU is connected directly to IDU SFP port (relay
application) or to EMM slave SFP port (add/drop configuration).
–
EMM Mode
– this function is related only to CFIP-16E1/T1-EXT module and allows to choose
traffic interface mode between E1 and T1
–
EMM Enable
– enables or disables generation/reception of data frames to/from Fiber Optic
stream. When enabled then particular EMM module occupies appropriate range of traffic port
channels
–
EMM Add/Drop ID
– specifies EMM Add/Drop Range – channel range which is in use by current
EMM module. In “auto” mode EMM module occupies port channel range according to its
position in EMM modules chain. In case of specific range of Add/Drop port channels, manual
Add/Drop ID setting is available as well.
–
EMM Add/Drop Range
– displays appropriate port channel range according to the EMM module
position and EMM Add/Drop ID setting.
Configuration menu of particular EMM (Expansion) module can be selected in dropdown box “EMM
selection”on the bottom of the EMM configuration page:
After selecting particular EMM module and pressing on “Change card without apply”, appropriate
EMM module’s configuration menu will be displayed: