Chapter 3 – Installation
Introduction
The installation of CFIP Phoenix C microwave system and its start up can perform only manufacturer´s
authorized partner. Manufacturer´s authorized partner is also liable for elimination of possible failures
and troubles in warranty period. The equipment must be installed according to country national
electrical codes. Power distribution to which the device will be connected has to meet the
requirements of current valid standards.
Required installation tools
List of installation tools necessary for perfect installation (not included in the delivery).
Table 3: List of necessary installation tools
Cross screwdriver
for IDU rack cabinet installation
Engineer´s wrench
M7, M10, M13, M17
Vulcanize isolation tape
for N and BNC connector insulation
DC voltmeter
for RSSI measurement on ODU
BNC – DC voltmeter reduction
for RSSI measurement
Unpacking the device
After unpacking the device, please, check that the delivery contains all the parts including the related
accessories. Complete list of parts as stated on „Packing list” is included in every delivery.
ODU installation
Setting the polarization
The polarization depends only on the ODU position and relevant adapter rotation. There is an arrow
symbol on the ODU case, that explicitly identifies the polarization. If the arrow points downwards or
turning ODU by 180
o
upwards, it is vertical polarization. Horizontal polarization is turned by 90
o