139
CFIP PhoeniX C Series TDM/IP Split Mount System Technical Description and Configuration Guide
•
Rev. 1.0
•
© SAF Tehnika JSC 2013
Miscellaneous
Table 9: Miscellaneous
Item
Parameter
Value
IDU Mechanical
Dimension [w x h x d]
210 mm x 44 mm x 250 mm
Weight
2 kg
Protection
IP31 (EN 60529)
ODU Mechanical
Dimension
Ø 295.2 mm; H: 92.5 mm
Weight
3.9 kg
Protection
IPx6 (EN 60529)
Input Voltage Level
IDU
-20 VDC up to -60 VDC
ODU
-30 VDC up to -60 VDC
Power
Consumption
IDU only
< 22 W (full port connection)
ODU only
< 38 Watts
IDU+ODU
< 60 Watts
Maximum ODU current
up to 1.9 A DC
Environmental
Operational
Conditions
IDU Temperature
-5° to +45°C
IDU Humidity
0 to 95%, Non condensing
ODU Temperature
-33° to +55°C
ODU Cold Start
Operational at -45°C, not guaranteed all specification
ODU Humidity
0 to 100%
Accessories
Table 10: External Power Supply Parameters
Power supply
85 VAC - 240 VAC
Input power
48 VDC ± 5%
Input frequency
47 Hz – 63 Hz
Operation temperature
0°C – 40°C
Protection
Surge and power guard, short-circuit protection
EMI
EN55022, EN55024
Dimensions H x W x D (cm)
3,7 x 6,5 x 16,7