30
CFIP PhoeniX C Series TDM/IP Split Mount System Technical Description and Configuration Guide
•
Rev. 1.0
•
© SAF Tehnika JSC 2013
Item
Parameter
Value
IDU direction interface
1x SFP 1000Base-SX (proprietary GIGE
protocol)
for connection with CFIP Phoenix C IDU
EXT module extension interface
1x SFP 1000Base-SX (proprietary GIGE
protocol)
for connection with additional EMM module
EXT module scalability
Up to 64 E1 / T1 with combination of 4x
EMM-16E1/T1 modules in series
Network Management System
Item
Parameter
Value
Ports
Main NMS ports
2x SFP 1000Base-SX (proprietary GIGE
protocol) from IDU
NMS form
Protocols
Proprietary
Management Speed
1Mbps
GUI
Type
WEB based as additional function of IDU,
folder PORTS
SNMP
Version
SNMP v1, SNMP v2c, SNMP v3 IDU support
Read access
Complete MIB IDU support
Write access
Sub-set of link parameter IDU support
Security
Licenses
Time limited/permanent IDU Support
Access levels
guest/user/admin with password security IDU
Support
Miscellaneous
Item
Parameter
Value
Mechanical
Dimension [w x h x d]
224mm x 44mm x 134mm
Weight
1,3 kg
Protection
EN 60529 (IP31)
Input Voltage Level
EMM only
-20 VDC up to -60 VDC (standard version)
Power
Consumption
CFIP-16 x E1/T1-EXT
< 9 W
Environmental
Operational
Conditions
Temperature
-5 ° to +45 °C
Humidity
0 to 95%, Non condensing
Altitude
4,500 Meters
Compliance
Operation
ETSI EN 300 019, Part 1-3, Class 3.2
Storage
ETSI EN 300 019, Part 1-1, Class 1.2
Transportation
ETSI EN 300 019, Part 1-2, Class 2.3
Power
EN 300 132-2
EMC
EN 55022 class B,
EN 61000-4-2,3,4,5,6,8,11