Design MULTI must by selected as the first step in configuration process on both IDUs.
Figure 86: Example 3
–
Selection of design MULTI at LOCATION 1
Then the proper IP address setting must entered and applied. The new login into system is
automatically required after applying any IP change. Such IP configuration change doesn't influence
data traffic (no data drop during IP reinitialization).
Figure 87: Example 3
–
IP address setting at LOCATION 1
Then most important step of such Out-off-Band management configuration is the proper VLAN and
ETH speed setting. Change VLAN Port Modes and Port Groups and apply it by pressing APPLY button.
Such change must be confirmed at the intermediate window by pressing Continue button (the remote
access to IDU must be ensured with similar VLAN configuration in your network otherwise previous
IDU1 (provider side)
IDU2 (customer side)
IDU3 (customer side)
Maintenance | Advanced
Design
multi
multi
multi
IP | Address
Local IP
10.10.10.10/24
10.10.10.9/24
10.10.10.8/24
Remote IP
10.10.10.9
10.10.10.10
10.10.10.7
Gateway IP
10.10.10.1
10.10.10.1
10.10.10.1
Ports | Parameters
Speed Allocation [Mbps]
ETH1 = 362
ETH2 = 1
ETH1 = 362
ETH2 = 1
ETH1 = 362
ETH2 = 1
Ports | ETH VLAN
Port Mode
basic = all ports
basic = all ports
basic = all ports
Port Groups
1 = lan3, mng, wanB
2 = lan1/2, wanA
1 = lan3, mng, wanB
2 = lan1/2, wanA
1 = lan2/3, mng, wanB
2 = lan1, wanA