1
Air Disinfection & Purification
Machine (FAST-Y-90A)
Installation & Operation Manual
Triple disinfection & purification technology Dynamic tracking & Remote intelligent control Remote intelligent control
Страница 1: ...1 Air Disinfection Purification Machine FAST Y 90A Installation Operation Manual Triple disinfection purification technology Dynamic tracking Remote intelligent control Remote intelligent control ...
Страница 2: ...Maintenance and Repair 5 Parts and Accessories 5 Summary 6 Product Overview 6 Application 6 Advantage 6 Assembly Drawing 6 Operation 8 Power on 8 Startup Shutdown 8 Brief Introduction of Touch Screen Functions 9 Maintenance 20 Maintenance Tips 20 Pre maintenance Work 21 Maintenance Operation 21 Maintenance of Purification System 23 Maintenance of Disinfection System 23 Maintenance of Deodorization...
Страница 3: ...tion Machine FAST Y 90A 3 Technical Parameters 25 Safety Instruction 26 External Power 26 Usage Position 26 Routine Maintenance and Inspection 26 Pre use Inspection 26 After sales Service 26 Technical Fault 26 System Upgrade 26 ...
Страница 4: ...Tips About User Manual Through the directory you can find the specified project quickly It is recommended to read the user manual carefully in order to understand your FAST air purifier Updates after finalization When the user s manual has been finalized if updates are necessary it shall be attached to the printed brief notes Additional Information If you have any further questions please feel fre...
Страница 5: ...pairing a defective part or device or if needed replacing the faulty part or unit with a new one according to the consideration of the salesperson is included in the warranty This operation shall only be permitted at the SHANGFENG After sales Service Center or agent by personnel with corresponding training in accordance with the provisions of SHANGFENG Company Possible travel expenses and freight ...
Страница 6: ... It is suitable for disinfection and purification of indoor air in Terminal building waiting room subway station hospital school exhibition hall museum library venue hotel shopping center supermarket cinema office building and other closed spaces Advantage Super large purification area super high purification flux and super strong pu rification effect Products have obtained CE certification the US...
Страница 7: ...Air Disinfection Purification Machine FAST Y 90A 7 Figure 2 Figure 3 ...
Страница 8: ...ed After the power is switched on the 4 1 red power indicator on the purifier lights up indicating that the power has been switched on Startup Shutdown Startup After the 4 1 red power indicator lights up press the 4 4 switch button the 4 2 green running indicator on the purifier will light up the touch screen will start up and the screen will light up indicating the purifier has entered standby mo...
Страница 9: ...en running indicator is off and the touch screen is off indicating that the device has been shut down Brief Introduction of Touch Screen Functions Figure 5 Running Lock on off Touch the running lock of the device to control its on and off The running lock indicator light will show the status Malfunction Tips When the unit fails the unit failure indicator 5 2 will flash indicating that the unit fai...
Страница 10: ...bout the using operation and precautions of the unit they can touch the 5 4 help button for help query Figure 6 Cumulative total purification volume purification volume per hour Users can check the cumulative purification volume and the purification volume per hour through the data displayed by the 5 5 meter PM2 5 Users can check the PM2 5 value under the current operating environment through the ...
Страница 11: ...nt through the 5 8 meter display Temperature Users can view the current operating environment temperature values through the 5 9 meter display Humidity Users can check the humidity value under the current operating environment through the 5 10 meter display Air purification status Touch the 5 11 Air Sterilization icon to inquire the daily and monthly disinfection time cumulative disinfection time ...
Страница 12: ...ir Disinfection Purification Machine FAST Y 90A Air purification status Touch the 5 12 Air Purification icon to query the daily and monthly purification time cumulative purification time and volume Figure 8 ...
Страница 13: ...Air Disinfection Purification Machine FAST Y 90A 13 Intelligent Control Touch 5 13 Intelligent Control icon to set the following functions Figure 9 ...
Страница 14: ...Air Purification on off Touch the 5 13 intelligent control icon on the touch screen then touch the purification fully on off button when the running lock of the device is on Touch the group on off button to select the purification function group on or off Purification Amount Touch the 5 13 intelligent control icon on the touch screen then touch the purification amount adjustment button when the ru...
Страница 15: ...Air Disinfection Purification Machine FAST Y 90A 15 Figure 10 ...
Страница 16: ...T Y 90A Fault Record If there is a fault during running time the 4 3 yellow indicator will light up and the 5 2 fault indicator light will flash indicating that there is a fault needs to debug Touch this button to view the fault record Figure 11 ...
Страница 17: ...Air Disinfection Purification Machine FAST Y 90A 17 About Device Touch this button to view information related to the device Figure 12 ...
Страница 18: ...18 Air Disinfection Purification Machine FAST Y 90A System Upgrade When the device is connected to the Internet touch this button to upgrade the system Figure 13 ...
Страница 19: ...Air Disinfection Purification Machine FAST Y 90A 19 Reboot Device Touch this button and confirm the dialogue to restart the device Figure 14 ...
Страница 20: ...ance Tips When the purifier reaches the condition of daily maintenance the 5 3 main tenance indicator above the touch screen lights up indicating that the unit needs maintenance After the maintenance finished touch the 5 3 maintenance indicator to en ter the maintenance interface as shown in Figure 15 Touch the completed maintenance project and the system can record the maintenance time and conten...
Страница 21: ...tinuously for more than 2 hours Disconnect the plug from the external power supply The maintenance work must be carried out in the unit state of power off Maintenance Operation Open access door No 7 Lift up from the lower access door the direction shown in Figure 16 to open it Figure 16 As is shown in Figure 17 insert the special key 12 of triangular lock the key is stored in the special tool box ...
Страница 22: ...22 Air Disinfection Purification Machine FAST Y 90A Figure 17 As is shown in Figure 18 draw out the purification module disinfection mod ule and deodorization module respectively Figure 18 ...
Страница 23: ...ntained once the unit has running 4 6 months or more than 4000 hours after last maintenance Important Note Before maintenance the disinfection module must work continuously for 2 hours and the unit maintenance can only be carried out under the condition of power off The service life of the ultraviolet lamp tube is 10000h The ultraviolet lamp tube should be replaced after the service life Otherwise...
Страница 24: ...to ensure the installation is in place Install the inner compartment sealing plate and lock it with the special key Install access door No 7 Align the access door with the buckle insert it from the top down and install the access door to ensure firm installation After each maintenance before use again try to run for 5 minutes to ensure the normal operation of the purifier ...
Страница 25: ...Staphylococcus white killing rate 99 9 99 9 Air natural bacteria extinction rate 90 0 90 0 Formaldehyde eliminate rate 87 5 87 5 Benzene eliminate rate 98 7 98 7 Operation mode Local Remote Local Remote Temperature 10 40 C 10 40 C Installation requirements Flat solid ground Flat solid ground Bottom wheel Adjustable universal wheel Adjustable universal wheel Notes The total air volume of the fan is...
Страница 26: ...ces in the transportation process of the product It should be thoroughly checked before use to ensure that the product is firm and safe to use After sales Service Tel 86 400 601 8390 Email sales i wind com Website www i wind com Technical Fault If you plug in the external power supply according to the instructions unit can not work normally Please open the access door 8 check whether the power lea...